External Cladding: Jointed 75mm Compleo Panel
External Cladding Top Hats: Topspan 61 (0.75BMT) or Knauf Top Hat 35 (0.75BMT)
Moisture Barrier: Breathable wall wrap
Frame: Minimum 92mm 1.15 BMT steel stud
Wall Insulation: Minimum R2.0 Earthwool
Internal Lining: As per table
System Number | Acoustic Rating Rw (Rw+Ctr) Acoustic Report 5008-17 |
FRL From Outside Fire Report FAR 4395 |
FRL From Inside Fire Report FAR 4395 |
Internal lining | System Image |
---|---|---|---|---|---|
KCEH1 | 55 (48) | 120/120/120 | NA | 13mm MastaShield | |
KCEH2 | 55 (49) | 120/120/120 | 60/60/60 | 16mm FireShield | |
KCEH3 | 57 (52) | 120/120/120 | 90/90/90 | 2 x 13mm FireShield | |
KCEH4 | 58 (52) | 120/120/120 | 120/120/120 | 2 x 16mm FireShield |
Table Notes:
1. FRL is unaffected by the insulation.
2. The Structural Adequacy component of the FRL refers to the stud.
3. MastaShield may be substituted with, 10mm SoundShield, 13mm WaterShield or 10mm Opal.
4. FireShield may be substituted with TruRock of the same thickness.